    "name": "Voltage Drop Calculator",
    "url": "https://calculators.geekmidst.com/calculators/voltage-drop-calculator",
    "markdown": "https://calculators.geekmidst.com/calculators/voltage-drop-calculator.md",
    "category": "Science & engineering",
    "description": "Estimate the voltage drop along a copper or aluminium cable from its size (mm² or AWG), length and current, for DC, single-phase or three-phase.",
    "summary": "Current flowing through a cable’s resistance loses some voltage before it reaches the load. The drop grows with current and length and falls as the conductor gets thicker.",
    "also_called": [
        "Cable voltage drop calculator",
        "Wire voltage drop calculator"
    ],
    "applies_to": "Worldwide",
    "last_updated": "2026-10-29",
    "computation": "Results are computed in the visitor’s browser on the HTML page. This API describes the calculator; it does not compute results.",
    "inputs": [
        {
            "name": "system",
            "label": "System",
            "type": "select",
            "default": "single",
            "options": {
                "dc": "DC (two wires)",
                "single": "Single-phase AC",
                "three": "Three-phase AC (balanced)"
            }
        },
        {
            "name": "voltage",
            "label": "Supply voltage",
            "type": "number",
            "default": "230",
            "unit": "V"
        },
        {
            "name": "current",
            "label": "Load current",
            "type": "number",
            "default": "16",
            "unit": "A"
        },
        {
            "name": "length",
            "label": "One-way cable length",
            "type": "number",
            "default": "30"
        },
        {
            "name": "length_unit",
            "label": "Length in",
            "type": "segmented",
            "default": "m",
            "options": {
                "m": "Metres",
                "ft": "Feet"
            }
        },
        {
            "name": "size_type",
            "label": "Conductor size as",
            "type": "segmented",
            "default": "mm2",
            "options": {
                "mm2": "mm²",
                "awg": "AWG"
            }
        },
        {
            "name": "area",
            "label": "Conductor cross-section",
            "type": "number",
            "default": "2.5",
            "unit": "mm²",
            "shown_when": {
                "size_type": "mm2"
            }
        },
        {
            "name": "awg",
            "label": "Wire gauge",
            "type": "select",
            "default": "12",
            "options": {
                "4/0": "4/0 AWG",
                "3/0": "3/0 AWG",
                "2/0": "2/0 AWG",
                "1/0": "1/0 AWG",
                "1": "1 AWG",
                "2": "2 AWG",
                "3": "3 AWG",
                "4": "4 AWG",
                "6": "6 AWG",
                "8": "8 AWG",
                "10": "10 AWG",
                "12": "12 AWG",
                "14": "14 AWG",
                "16": "16 AWG",
                "18": "18 AWG",
                "20": "20 AWG",
                "22": "22 AWG",
                "24": "24 AWG"
            },
            "shown_when": {
                "size_type": "awg"
            }
        },
        {
            "name": "material",
            "label": "Conductor",
            "type": "segmented",
            "default": "copper",
            "options": {
                "copper": "Copper",
                "aluminium": "Aluminium"
            }
        },
        {
            "name": "temperature",
            "label": "Conductor temperature",
            "type": "number",
            "default": "20",
            "unit": "°C",
            "optional": true
        }
    ],
    "outputs": [
        {
            "key": "drop_volts",
            "label": "Voltage drop",
            "format": "number"
        },
        {
            "key": "drop_percent",
            "label": "Drop as a share of supply",
            "format": "percent"
        },
        {
            "key": "load_voltage",
            "label": "Voltage at the load",
            "format": "number"
        },
        {
            "key": "conductor_area",
            "label": "Conductor cross-section",
            "format": "number"
        },
        {
            "key": "ohm_per_km",
            "label": "Conductor resistance",
            "format": "number"
        },
        {
            "key": "loss_watts",
            "label": "Power lost in the cable",
            "format": "number"
        }
    ],
    "formula": {
        "text": "R = ρ × L ÷ A × (1 + α(T − 20 °C));  DC and single-phase: Vd = 2 × I × R;  three-phase: Vd = √3 × I × R",
        "variables": {
            "ρ": "resistivity at 20 °C: copper 0.017241 Ω·mm²/m (1/58, 100% IACS), aluminium 0.028265 (61% IACS)",
            "L": "one-way length (m)",
            "A": "cross-section (mm²); AWG uses d = 0.127 mm × 92^((36 − n)/39)",
            "α": "temperature coefficient: copper 0.00393, aluminium 0.00403 per °C",
            "I": "load current (A)"
        }
    },
    "worked_example": {
        "inputs": {
            "system": "single",
            "voltage": "230",
            "current": "16",
            "length": "30",
            "length_unit": "m",
            "size_type": "mm2",
            "area": "2.5",
            "awg": "12",
            "material": "copper",
            "temperature": "20"
        },
        "steps": [
            "Resistance of one conductor: 0.017241 × 30 ÷ 2.5 = 0.2069 Ω.",
            "Single-phase current flows out and back: Vd = 2 × 16 × 0.2069 = 6.62 V.",
            "6.62 ÷ 230 = 2.88% of the supply, leaving 223.38 V at the load."
        ],
        "result": "16 A over 30 m of 2.5 mm² copper drops about 6.6 V (2.9%) on a 230 V single-phase circuit at 20 °C."
    },
    "interpretation": "Wiring rules set maximum drops, often a few per cent depending on the country and the type of circuit. If the result is close to your limit, use a larger conductor or a shorter route, and repeat the calculation at the cable’s operating temperature.",
    "assumptions": [
        "Resistive drop only: cable reactance and load power factor are ignored, which is accurate for small and medium cables at mains frequency.",
        "Three-phase loads are balanced."
    ],
    "limitations": [
        "Cable sizing must also meet current-carrying capacity, fault protection and installation rules set by your local wiring regulations.",
        "Very large conductors (above about 50 mm²) need reactance included; use the manufacturer’s mV/A/m data."
    ],
    "rules": null,
    "faqs": [
        {
            "question": "Why multiply by 2 for single-phase?",
            "answer": "Current goes out along one conductor and returns along the other, so the cable length is effectively doubled. In a balanced three-phase circuit the factor is √3 instead."
        },
        {
            "question": "Which temperature should I use?",
            "answer": "For a quick check use 20 °C. For a design check use the cable’s maximum operating temperature (for example 70 °C for PVC insulation), which raises copper resistance by about 20%."
        }
    ],
    "sources": [],
    "related": [
        {
            "name": "Ohm’s Law Calculator",
            "url": "https://calculators.geekmidst.com/calculators/ohms-law-calculator"
        },
        {
            "name": "Resistor Calculator",
            "url": "https://calculators.geekmidst.com/calculators/resistor-calculator"
        },
        {
            "name": "Length Converter",
            "url": "https://calculators.geekmidst.com/calculators/length-converter"
        }
    ],
    "disclaimer": "Quantities are estimates. Confirm requirements with your engineer or supplier before ordering materials.",
    "publisher": "GM¹X CalcVerse"
}